+1(781)975-1541
support-global@metwarebio.com

The Lowry Protein Assay: A Time-Tested Method for Protein Quantification

Protein quantification is a fundamental process in biochemistry and molecular biology. Accurate protein concentration measurements are essential for a wide range of applications, from enzyme kinetics studies to the characterization of cellular proteins. While several methods have been developed over the years to measure protein content, the Lowry Protein Assay remains one of the most widely used techniques due to its high sensitivity, precision, and reliability. Since its introduction by Oliver H. Lowry and colleagues in 1951, this method has been extensively applied in research laboratories across multiple scientific disciplines.

Despite the emergence of newer protein quantification assays, the Lowry method continues to be valued for its ability to detect low protein concentrations with high accuracy. However, as with any scientific technique, it has its strengths and limitations. This article provides a comprehensive overview of the Lowry assay, covering its principle, step-by-step methodology, applications, potential interferences, and a comparison with alternative protein quantification methods. Understanding these aspects can help researchers determine when and how to use the Lowry method effectively for their protein analysis needs.

 

 

Understanding the Biochemical Principle of the Lowry Assay

The Lowry Protein Assay is based on two key colorimetric reactions, which result in the formation of a colored product whose intensity is directly proportional to the protein concentration. These reactions involve the Biuret reaction and the Folin-Ciocalteu reduction reaction, both of which contribute to the assay's specificity and sensitivity.

The first step in the assay relies on the Biuret reaction, where proteins react with copper ions (Cu²⁺) under alkaline conditions. The peptide bonds present in proteins chelate Cu²⁺ ions, forming a complex that exhibits a light blue coloration. This reaction alone is the basis of another protein assay called the Biuret test, but in the Lowry method, it serves as a precursor to a second, more sensitive reaction. Following the Biuret reaction, the assay employs Folin-Ciocalteu reagent, which interacts specifically with certain amino acid residues, primarily tyrosine, tryptophan, and cysteine. These amino acids reduce the Folin-Ciocalteu reagent, leading to the formation of a deep blue color. The intensity of this color is measured spectrophotometrically at 750 nm, and since the color development is proportional to protein concentration, a standard curve is used to quantify unknown protein samples accurately.

The combination of these two reactions provides greater sensitivity than the Biuret assay alone. The Lowry method can detect protein concentrations as low as 10 µg/mL, making it suitable for measuring low protein levels in biological samples. However, because it relies on the presence of specific amino acids, different proteins may exhibit slightly different responses, requiring careful calibration.

 

Step-by-Step Protocol for Accurate Protein Measurement

To achieve accurate and reproducible results, the Lowry assay must be performed meticulously, ensuring that all reagents are prepared correctly, reaction times are maintained, and potential interferences are minimized. Below is a detailed protocol outlining the experimental setup and measurement steps.

Step 1: Preparing the Standard Curve

A standard curve is essential for accurately determining protein concentrations by comparing absorbance readings to known values. To begin, a series of Bovine Serum Albumin (BSA) standards at concentrations of 0, 10, 20, 50, and 100 µg/mL should be prepared, ensuring that each concentration is tested in duplicate or triplicate to enhance precision. Once the standards are prepared, 1 mL of Lowry Reagent A is added to each tube, followed by thorough mixing. The reaction is then allowed to proceed for 10 minutes at room temperature, during which the Biuret reaction takes place. After this incubation period, 0.1 mL of Lowry Reagent B is added to each tube, ensuring complete mixing, and the reaction is allowed to develop for 30 minutes at room temperature, preferably in the dark to protect the Folin-Ciocalteu reagent from light-induced degradation. Finally, the absorbance of each standard is measured at 750 nm using a spectrophotometer. The resulting data are plotted on a graph to establish a standard curve, where absorbance is plotted against protein concentration, providing a reference for determining the protein content in unknown samples.

Step 2: Measuring Protein Concentration in Unknown Samples

Once the standard curve is established, the protein concentration of unknown samples can be determined using the same procedure. Each test protein sample is prepared using the same buffer conditions as the standards to ensure consistency in readings. 1 mL of Lowry Reagent A is added to the sample, followed by thorough mixing, and the mixture is incubated at room temperature for 10 minutes to allow for the initial copper-protein complex formation. Next, 0.1 mL of Lowry Reagent B is added to each sample, mixed thoroughly, and allowed to develop for 30 minutes at room temperature, ensuring uniform reaction conditions for color formation. After incubation, the absorbance is measured at 750 nm, and the protein concentration is determined by referring to the previously generated standard curve. To maintain accuracy, samples with absorbance values exceeding the highest standard concentration should be appropriately diluted and reanalyzed. This ensures that all measurements fall within the linear range of the assay, preventing overestimation or underestimation of protein concentration. Applications of the Lowry Assay in Research

 

Applications of the Lowry Assay in Research

The Lowry Protein Assay is widely employed across biochemistry, molecular biology, and biomedical research due to its high sensitivity and broad applicability in quantifying protein concentrations in various biological samples. One of its most common applications is the quantification of total protein content in cell lysates and tissue extracts, which is crucial for assessing protein expression levels in different experimental conditions. In clinical and diagnostic studies, the assay is frequently used for measuring serum and plasma protein concentrations, providing valuable insights into physiological and pathological conditions. Additionally, it plays an essential role in enzyme research, where accurate protein quantification is necessary to determine enzyme purity, activity, and kinetic parameters. Beyond the biomedical field, the Lowry assay finds applications in food science and nutrition, where it is used to determine protein content in various food products, including dairy, cereals, and meat. Due to its ability to detect low protein concentrations with high precision, the assay is particularly useful in studies requiring sensitive and reproducible measurements. However, despite its robustness, researchers must carefully consider potential interferences and optimize assay conditions to ensure the most reliable results.

 

Limitations and Potential Interferences in the Lowry Method

Despite its advantages, the Lowry Protein Assay is not free from limitations. Some key challenges include:

1. Interference from Reducing Agents and Detergents – Compounds such as DTT, β-mercaptoethanol, SDS, and Triton X-100 can interfere with the copper-protein complex formation, leading to inaccurate readings.

2. Sample Buffer Composition – Strong alkaline buffers or high salt concentrations can alter color development and absorption properties.

3. Variability Among Different Proteins – Because the assay depends on amino acids like tyrosine and tryptophan, proteins with low concentrations of these residues may give underestimated values.

To mitigate these issues, researchers should optimize sample preparation, remove interfering substances, and ensure consistent incubation conditions.

 

Comparing the Lowry Assay with Other Protein Quantification Techniques

Several other protein assays are available, each with unique advantages and limitations:

Method

Lowry Assay

BCA Assay

Bradford Assay

Principle

Biuret + Folin-Ciocalteu reaction

Biuret + BCA-Cu complex reaction

Coomassie dye binding

Sensitivity

High (10-100 µg/mL)

Medium (50-500 µg/mL)

Medium (50-500 µg/mL)

Precision

High (±5%)

Moderate (±10%)

Moderate (±10%)

Interference

Sensitive to reducing agents, detergents

Sensitive to reducing agents, chelators

Sensitive to detergents, strong acids/bases

Cost

Moderate

High

Low

Time Required

~40 minutes

~30 minutes

~5 minutes

 

Final Thoughts: Why the Lowry Assay Remains a Gold Standard

The Lowry Protein Assay has remained a preferred method for protein quantification for over 70 years due to its high sensitivity, accuracy, and broad application range. Although newer methods such as the BCA assay and Bradford assay have gained popularity, the Lowry assay is still widely used for low-concentration protein samples where high precision is required.

When choosing a protein quantification method, researchers must consider sample composition, potential interferences, time constraints, and required sensitivity. By carefully following the experimental protocol and addressing potential limitations, the Lowry method continues to be a reliable and valuable tool for protein analysis in modern laboratories.

 

Reference

1. LOWRY, O H et al. “Protein measurement with the Folin phenol reagent.” The Journal of biological chemistry vol. 193,1 (1951): 265-75.

2. Waterborg, J H, and H R Matthews. “The Lowry method for protein quantitation.” Methods in molecular biology (Clifton, N.J.) vol. 32 (1994): 1-4. doi:10.1385/0-89603-268-X:1

3. Sapan, Christine V, and Roger L Lundblad. “Review of methods for determination of total protein and peptide concentration in biological samples.” Proteomics. Clinical applications vol. 9,3-4 (2015): 268-76. doi:10.1002/prca.201400088

 

Read more

Total Protein Quantification Methods: BCA vs. Bradford

WHAT'S NEXT IN OMICS: THE METABOLOME

Please submit a detailed description of your project. We will provide you with a customized project plan metabolomics services to meet your research requests. You can also send emails directly to support-global@metwarebio.com for inquiries.
Name can't be empty
Email error!
Message can't be empty
CONTACT FOR DEMO
+1(781)975-1541
LET'S STAY IN TOUCH
submit
Copyright © Metware Biotechnology Inc. All Rights Reserved.
support-global@metwarebio.com +1(781)975-1541
8A Henshaw Street, Woburn, MA 01801
Contact Us Now
Name can't be empty
Email error!
Message can't be empty